Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
J Hand Surg Eur Vol ; : 17531934241242004, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38534148

RESUMO

We investigated the efficacy of the supination-external rotation ('Sup-ER') orthosis, designed as a non-operative treatment to maintain normal anatomical growth of the shoulder, on the progression of glenohumeral dysplasia in patients with brachial plexus birth injuries. The Sup-ER orthosis was fabricated for 20 infants diagnosed with glenohumeral dysplasia after brachial plexus birth injuries and its success in correcting glenohumeral dysplasia was confirmed by objective calculations of the alpha angle on serial ultrasound findings and improvement in Active Movement Scale scores. Of the 20 patients, 14 had successful resolution of glenohumeral dysplasia, confirmed by shoulder abduction, shoulder flexion, external rotation and supination, Active Movement Scale scores and improving alpha angle measurements. Failure to rectify glenohumeral dysplasia, evidenced by worsening ultrasound findings and Active Movement Scale scores, necessitated a change to operative management in six patients.Level of evidence: IV.

2.
Cureus ; 16(1): e52250, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38352113

RESUMO

Brachial plexus birth injury (BPBI) is a relatively common condition that poses a significant challenge to children who endure functional impairments later on. This comprehensive bibliometric analysis sought to quantitatively evaluate the existing literature on BPBI, shedding light on authorship, collaboration, publication trends, and keyword analysis to both inform the medical community and foster future research growth. A thorough search of the Web of Science database yielded 712 relevant documents published between 1986 and 2022. The analysis utilized Biblioshiny (K-Synth Srl, Naples, Italy) for bibliometric data, alongside VOSviewer (Centre for Science and Technology Studies, Leiden University, The Netherlands) and TextRazor (TextRazor Ltd., London, UK) for keyword categorization. The literature had an average annual growth rate of 7.94%, with an average document age of 12 years. Collaborative efforts demonstrated 9.6% international co-authorship, with the United States prominently leading global collaborations. Top producing authors included Yang, Kozin, and Clarke, while the most cited authors were Clarke, Waters, and Curtis. Journals such as the Journal of Pediatric Orthopedics and Plastic and Reconstructive Surgery emerged as key contributors to the literature. Keyword analysis illuminated prevalent categories like "society" and "health," underscoring the multifaceted nature of BPBI research. The findings from this bibliometric analysis highlight the dynamic and collaborative landscape of BPBI research, emphasizing the pressing need for continued contributions to address existing gaps in knowledge, enhance global collaboration, and advance the understanding and treatment of this complex condition. Beyond quantitative metrics, this study holds particular significance in its role as a compass for researchers, practitioners, and policymakers invested in BPBI. By offering insights into influential authors, institutions, and emerging trends, this analysis serves as a valuable resource, guiding future research endeavors, fostering interdisciplinary collaboration, and ultimately contributing to improved outcomes for individuals affected by BPBI. The importance of this study lies not only in its informative content but also in its potential to catalyze a collective effort toward refining treatment modalities, promoting preventative measures, and enhancing the overall quality of care for those navigating the challenges of BPBI.

3.
Childs Nerv Syst ; 40(4): 1159-1167, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38353693

RESUMO

PURPOSE: Brachial plexus birth injury (BPBI) is a common injury with the spectrum of disease prognosis ranging from spontaneous recovery to lifelong debilitating disability. A common sequela of BPBI is glenohumeral dysplasia (GHD) which, if not addressed early on, can lead to shoulder dysfunction as the child matures. However, there are no clear criteria for when to employ various surgical procedures for the correction of GHD. METHODS: We describe our approach to correcting GDH in infants with BPBIs using a reverse end-to-side (ETS) transfer from the spinal accessory to the suprascapular nerve. This technique is employed in infants that present with GHD with poor external rotation (ER) function who would not necessitate a complete end-to-end transfer and are still too young for a tendon transfer. In this study, we present our outcomes in seven patients. RESULTS: At presentation, all patients had persistent weakness of the upper trunk and functional limitations of the shoulder. Point-of-care ultrasounds confirmed GHD in each case. Five patients were male, and two patients were female, with a mean age of 3.3 months age (4 days-7 months) at presentation. Surgery was performed on average at 5.8 months of age (3-8.6 months). All seven patients treated with a reverse ETS approach had full recovery of ER according to active movement scores at the latest follow-up. Additionally, ultrasounds at the latest follow-up showed a complete resolution of GHD. CONCLUSION: In infants with BPBI and evidence of GHD with poor ER, end-to-end nerve transfers, which initially downgrade function, or tendon transfers, that are not age-appropriate for the patient, are not recommended. Instead, we report seven successful cases of infants who underwent ETS spinal accessory to suprascapular nerve transfer for the treatment of GHD following BPBI.


Assuntos
Traumatismos do Nascimento , Neuropatias do Plexo Braquial , Plexo Braquial , Transferência de Nervo , Lactente , Criança , Humanos , Masculino , Feminino , Recém-Nascido , Transferência de Nervo/métodos , Neuropatias do Plexo Braquial/cirurgia , Estudos Retrospectivos , Nervo Acessório/cirurgia , Traumatismos do Nascimento/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
4.
J Surg Case Rep ; 2023(10): rjad549, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37846420

RESUMO

PIK3CA-related overgrowth spectrum (PROS) is a heterogeneous group of diseases, with varied clinical presentations ranging from isolated segmental overgrowths to megalencephaly and vascular malformations, all resulting from post-zygotic activating mutations in PIK3CA. Isolated macrodactyly of upper limb is extremely rare, accounting only for 0.9%-1% of all congenital anomalies of the upper limb. This report describes a case of congenital, isolated, nonprogressive macrodactyly of the right index finger and thumb, in an adult patient that was treated with debulking surgery. The microscopic features were compatible with lipomatosis of nerve. Due to the prompt and pertinent molecular testing, which identified a somatic PIK3CA variant, c.3140A > G, p.H1047R., the case was classified as a PROS. The availability of mTOR inhibitors offers additional treatment possibilities in cases with progressive disease. This case report highlights the importance of molecular testing to identify PROS, to further the knowledge of this continually expanding entity.

5.
J Shoulder Elbow Surg ; 32(5): 1074-1078, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36736655

RESUMO

BACKGROUND: In nonoperative management of displaced olecranon fractures, patients are able to maintain overhead extension despite a persistent nonunion. It has been hypothesized that this is feasible because of an intact lateral cubital retinaculum. The purpose of this biomechanical study was to determine the contribution of the medial and lateral cubital retinacula to overhead extension in the setting of a displaced olecranon fracture. METHODS: Eight fresh-frozen cadaveric upper-extremity specimens were used in this study. The triceps muscle was loaded through a pulley system operated by an Instron 8874 Biaxial Servohydraulic Fatigue Testing System at a rate of 10 mm/second to simulate overhead elbow extension. Each specimen was tested in 4 states: (1) native state with an intact olecranon; (2) transverse olecranon fracture; (3) transection of 1 cubital retinaculum (medial or lateral); and (4) transection of both medial and lateral cubital retinacula. The primary outcome was the ability to perform overhead extension. The secondary outcome was the force needed to generate extension. RESULTS: Elbow extension was noted in each specimen for trials 1, 2, and 3. Only when both the lateral fascia and medial fascia were transected was elbow extension not achieved. There was no significant difference in the force required to generate extension in the first 3 trials (P = .99). There was no significant difference in the change in the maximum force required to achieve extension between the specimens with only the medial side transected and the specimens with only the lateral side transected (P = .07). DISCUSSION: In the setting of an olecranon fracture, this biomechanical study suggests that if either the lateral or medial cubital retinaculum remains in continuity with the distal ulna, active overhead extension can be maintained. This finding may explain the positive clinical outcomes of nonoperative management of displaced olecranon fractures in the elderly patient population. Determining the integrity of the fascial structures preoperatively may help select candidates for nonoperative treatment of displaced olecranon fractures.


Assuntos
Articulação do Cotovelo , Fraturas Ósseas , Fratura do Olécrano , Olécrano , Fraturas da Ulna , Humanos , Idoso , Cotovelo/cirurgia , Antebraço , Articulação do Cotovelo/cirurgia , Olécrano/cirurgia , Fraturas da Ulna/cirurgia , Fáscia , Resultado do Tratamento , Fixação Interna de Fraturas
6.
Plast Surg (Oakv) ; 31(1): 61-69, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36755815

RESUMO

Background: Upper extremity (UE) microsurgical reconstruction relies upon proper wound healing for optimal outcomes. Cigarette smoking is associated with wound healing complications, yet conclusions vary regarding impact on microsurgical outcomes (replantation, revascularization, and free tissue transfer). We investigated how smoking impacted 30-day standardized postoperative outcomes following UE microsurgical reconstruction. Methods: Utilizing the National Surgical Quality Improvement Program, all patients who underwent (1) UE free flap transfer (n = 70) and (2) replantation/revascularization (n = 270) were identified. For each procedure, patients were stratified by recent smoking history (current smoker ≤1-year preoperatively). Baseline demographics and standardized 30-day complications, reoperations, and readmissions were compared between smokers and nonsmokers. Results: Replantation/revascularization patients had no differences in sex, race, or body mass index between smokers (n = 77) and nonsmokers. Smokers had a higher prevalence of congestive heart failure (5.2% vs 1.0%, P = .036) and nonsmokers were more often on hemodialysis (15.6% vs 10.4%, P = .030). Free flap transfer patients had no differences in age, sex, or race between smokers (n = 14) and nonsmokers. Smokers had a longer length of stay (6.6 vs 4.2 days, P = .001) and a greater prevalence of chronic obstructive pulmonary disorder (COPD; 7.1% vs 0%, P = .044). Recent smoking was not associated with increased odds of any 30-day minor and major standardized surgical complications, readmissions, or reoperations following UE microsurgical reconstruction via free flap transfer or replantation/revascularization. Baseline diagnosis of COPD was also not a predictor of adverse 30-day outcomes following free flap transfer. Conclusion: Recent smoking history was not associated with any 30-day adverse outcomes following UE microsurgical reconstruction via replantation/revascularization or free flap transfer. In light of these findings, further investigation is warranted, with particular focus on adverse events specific to free flaps and replantation/revascularization.


Contexte: La reconstruction microchirurgicale du membre supérieur repose sur la bonne guérison de la plaie pour des résultats optimaux. Le tabagisme est associé à des complications pour la guérison des plaies; toutefois, les conclusions concernant ses répercussions sur les résultats microchirurgicaux (réimplantation, revascularisation et transfert de tissu libre) sont variables. Nous avons cherché à savoir quelles étaient les répercussions du tabagisme sur les résultats postopératoires standardisés à 30 jours après reconstruction microchirurgicale du membre supérieur. Méthodes: Utilisant le Programme national d'amélioration de la qualité de la chirurgie, tous les patients ayant subi (1) un transfert de lambeau libre du membre supérieur (n = 70) et (2) une réimplantation/revascularisation (n = 270) ont été identifiés. Pour chaque procédure, les patients ont été classés en fonction de leurs antécédents de tabagisme récent (fumeur actuel ≤ 1 an préopératoire). Les données démographiques initiales et les complications standardisées à 30 jours, les réinterventions et les réhospitalisations ont été comparées entre fumeurs et non-fumeurs. Résultats: Concernant les réimplantations/revascularisations, il n'y a pas eu de différences en termes de sexe, race ou IMC entre les fumeurs (n = 77) et les non-fumeurs. Les fumeurs avaient une plus grande prévalence d'insuffisance cardiaque congestive (5,2 % contre 1,0 %, P = 0,036) et les non-fumeurs étaient plus souvent sous hémodialyse (15,6 % contre 10,4 %, P = 0,030). Concernant les patients ayant eu un transfert de lambeau libre, il n'y a pas eu de différences en termes d'âge, de sexe ou de race entre les fumeurs (n = 14) et les non-fumeurs. La durée d'hospitalisation des fumeurs a été plus longue (6,6 jours contre 4,2 jours, P =0,001) avec une prévalence plus élevée de MPOC (7,1 % contre 0 %, P = 0,044). Le tabagisme récent n'a pas été associé à une augmentation de la probabilité de complications chirurgicales standardisées, majeures ou mineures, à 30 jours, de réhospitalisation ou reprises chirurgicales après reconstruction microchirurgicale du membre supérieur par transfert de lambeau libre ou réimplantation/revascularisation. Le diagnostic de MPOC à l'inclusion dans l'étude n'était pas non plus un facteur prédictif d'événements indésirables à 30 Jours après transfert de lambeau libre. Conclusion: Un antécédent de tabagisme récent n'a pas été associé à des résultats indésirables à 30 jours après reconstruction microchirurgicale du membre supérieur via réimplantation/revascularisation ou transfert de lambeau libre. À la lumière de ces constatations, des études supplémentaires portant particulièrement sur les événements indésirables propres aux procédures de lambeaux libres et de réimplantation/revascularisation sont justifiées.

7.
Plast Reconstr Surg Glob Open ; 11(1): e4756, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36655028

RESUMO

The wide awake local anesthesia no tourniquet (WALANT) technique has been proven to be safe and effective for upper extremity surgery. WALANT does not require extensive medical clearance and allows for intraoperative assessment of range of motion. Additionally, it is frequently associated with lower costs and less postoperative pain when compared with traditional methods of anesthesia. Despite its expanded use for hand procedures, there are sparse data to support the use of WALANT in local and regional soft tissue flaps. Methods: A retrospective review was performed. Twenty-one patients who underwent a local or regional soft tissue flap surgery using the WALANT technique from February 2, 2018 to February 25, 2022 were included in our analysis. Results: Overall, one Louvre flap, two posterior tibial artery perforator propeller flaps, two reverse radial forearm flaps, two Quaba flaps, six cross finger flaps, one reverse homodigital island flap, three first dorsal metacarpal artery flaps, two thenar flaps, and two Moberg flaps were performed. Patients were followed up for an average of 11.9 ± 8.1 weeks. During this time, no postoperative complications occurred. All patients demonstrated appropriate healing at donor and recipient sites. Full range of motion was regained for all patients. Conclusions: WALANT is safe and effective for use in local and regional soft tissue flap surgery. Surgeons should consider this technique for more involved procedures such as flap surgery, as preliminary results demonstrate positive outcomes and potentially superior recovery for patients.

8.
Hand (N Y) ; 18(6): 938-944, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-35156413

RESUMO

BACKGROUND: Surgical approaches to the proximal interphalangeal (PIP) joint often require disruption of soft tissue stabilizers. Additionally, PIP joint injuries frequently result in soft tissue disruption. This study evaluates the necessity of repairing soft tissue stabilizers by assessing their role in maintaining native joint congruity. METHODS: Eight specimens were used to evaluate congruity at 0° and 30° flexion when loaded with 2 N of valgus force. This was performed in the native joint and after sequential sectioning of the surrounding ligaments in order: volar plate (VP), radial collateral ligament (CL), and ulnar CL. The skin flap was sutured with the ligaments unrepaired and the load was reapplied. Radiographs were taken after each load and used to measure the joint line convergence angle (JLCA). RESULTS: Mean JLCA increased in both degrees of flexion after ligaments were sectioned but was only significantly different from the native joint after the VP was disrupted along with 1 CL. Joint congruity improved following repair of the skin flap in both degrees of flexion but was not significant. Joints were more congruent in 30° flexion for all subgroups, but none were significantly different compared to 0° flexion. CONCLUSIONS: Disruption of the VP is insufficient to significantly alter PIP joint congruity. While sectioning of both the VP and CLs resulted in a statistically significant change in joint congruity, mean JLCA demonstrated changes of minor clinical significance. The osseous anatomy of the phalanges imparts inherent stability that maintains a congruent joint despite loss of the soft tissue stabilizers.


Assuntos
Ligamento Colateral Ulnar , Falanges dos Dedos da Mão , Humanos , Articulações dos Dedos/diagnóstico por imagem , Articulações dos Dedos/cirurgia , Articulações dos Dedos/anatomia & histologia , Ligamentos Articulares , Amplitude de Movimento Articular
9.
J Hand Surg Am ; 48(1): 89.e1-89.e9, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34823921

RESUMO

PURPOSE: Differences in range of motion, pinch strength, biomechanical strength, or joint angulation have previously been investigated for various means of treatment of ulnar collateral ligament (UCL) tears. We sought to address a gap in the literature by comparing thumb metacarpophalangeal (MCP) joint angle measurements and biomechanical strength before complete, acute UCL tear and after repair with suture anchors (SA), suture tape (ST) anchor augmentation, or reconstruction with palmaris longus graft (PL). METHODS: Thumbs and, if present, the PL tendon were harvested from 15 fresh-frozen cadavers. Each thumb specimen was secured into a servohydraulic biomechanical testing frame to evaluate native radiographic MCP joint angles at 0° flexion when loaded with 0, 5, and 13 N of radial force. Subsequently, a single hand surgeon (S.M.K.) performed complete transection and UCL repair via 1 of 3 methods: SA (n = 5), ST (n = 5), or reconstruction with PL (n = 5). Following repair, MCP joint angles were radiographically evaluated. Specimens that did not fail during joint angle testing were transferred to a separate testing frame for load-to-failure testing. Angle measurements and mean load-to-failure were compared between the groups, and angulation was also compared with each group's native control. RESULTS: Both ST and SA groups demonstrated comparable stiffness to their native controls, whereas the PL group was significantly more lax. The ST repair was significantly stiffer than the other constructs. ST also required higher forces to reach failure compared to both SA and PL. No difference was found between SA and PL groups. CONCLUSIONS: Although both ST and SA constructs recapitulate native joint stiffness, repair with ST demonstrated the greatest biomechanical strength in stiffness and load-to-failure. CLINICAL RELEVANCE: For complete, acute tears of the thumb UCL, ST may be superior for maintaining MCP joint stability and strength over SA and PL.


Assuntos
Ligamento Colateral Ulnar , Ligamentos Colaterais , Humanos , Ligamento Colateral Ulnar/cirurgia , Polegar/cirurgia , Tendões/transplante , Músculo Esquelético , Âncoras de Sutura , Cadáver , Fenômenos Biomecânicos , Ligamentos Colaterais/cirurgia
10.
Orthopedics ; 46(3): e143-e148, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35876773

RESUMO

Evaluating the impact of articles can be performed through bibliometric analysis or social media impact using the Altmetric Attention Score (AAS). The purpose of this study was to report on the social media impact of peripheral nerve studies; how article demographic factors, such as journal specialty (hand, orthopedics, plastic surgery), affect AAS; and how AAS correlates with bibliometrics, namely citation number. While orthopedic journals received the highest academic attention, there was no significant difference in social media attention between journal groups. These findings suggest AAS may be useful to authors in deciding which journal in which to pursue publication. [Orthopedics. 2023;46(3):e143-e148.].


Assuntos
Ortopedia , Mídias Sociais , Humanos , Fator de Impacto de Revistas , Bibliometria
11.
J Hand Surg Asian Pac Vol ; 27(6): 957-965, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36476087

RESUMO

Background: The recently validated Hand Questionnaire (HAND-Q) is a multifaceted patient-reported outcome measure (PROM) for hand/upper extremity (UE) pathology and treatment. Here, we conduct a pilot study utilising data collected as a participating site for the Phase II HAND-Q Pilot Multicenter International Validation Study. We hypothesised that self-reported hand functionality, symptom/disease severity, hand appearance, emotional dissatisfaction and treatment satisfaction would be worse in patients who perceived their disease severity to be more severe but would not differ between patients based on prior surgical history. Methods: Patients were prospectively enrolled for HAND-Q participation from September 2018 to August 2019. Patients were included in this analysis if they responded to the following scales of HAND-Q: Hand Functionality Satisfaction, Symptom Severity, Hand Appearance Satisfaction, Emotional Dissatisfaction and Treatment Satisfaction. Composite scores (CS) were created for each section. Surgical versus non-surgical CS and mild versus moderate/severe CS were compared with t-tests. Bi-variate comparisons of responses were performed between surgical and non-surgical groups, and between mild and moderate/severe groups. Results: HAND-Q individual question analysis revealed significant differences in functionality and symptom severity for patients with prior surgery (p < 0.047). CS analysis confirmed greater overall impairment in surgical patients, but no overall impact on symptom severity. Regarding disease severity HAND-Q individual question analysis, moderate/severe patients reported worse outcomes for specific aesthetic qualities and symptoms for almost all items (p < 0.05). CS analysis revealed significantly worse overall hand appearance satisfaction, hand functionality, emotional satisfaction and symptom severity for patients with moderate/severe hand conditions. Conclusions: HAND-Q revealed worsened outcomes for UE patients with self-reported moderate/severe conditions or previous surgical history. Understanding how previous surgery and disease severity may impact clinical outcomes is important for crafting appropriate treatment. Level of Evidence: Level II (Prognostic Study).


Assuntos
Satisfação do Paciente , Extremidade Superior , Humanos , Projetos Piloto , Extremidade Superior/cirurgia , Medidas de Resultados Relatados pelo Paciente , Prognóstico
12.
J Hand Surg Glob Online ; 4(6): 452-455, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36420465

RESUMO

Wide-awake local anesthesia no-tourniquet (WALANT) surgery is an attractive option for hand surgeons, particularly during resource-scarce periods, as it eliminates dependence on main operating rooms or hospital-based procedures. The limited prepping or draping used for WALANT field sterility is as effective, if not more effective, than standard sterile prepping or draping. Patient anxiety surrounding WALANT surgery is similar to or less than that of general or local anesthesia with or without tourniquet. Patients use the same or lower amounts of postoperative narcotics after WALANT as compared to after the other anesthetic methods. Wide-awake local anesthesia no-tourniquet surgery saves significant costs for the same surgeries when performed under general or local anesthesia with or without tourniquet. There are very few complications associated with the WALANT method of anesthesia; rare case reports include vasovagal syncope and cardiac arrhythmia due to inadvertent intravascular injection of epinephrine.

13.
Plast Reconstr Surg Glob Open ; 10(10): e4600, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36299820

RESUMO

Using the hand questionnaire (HAND-Q) patient-reported outcome measure, the effects of upper extremity surgery on patients' perception of their sex life were explored. The hand is a uniquely sexual organ, and we hypothesized that self-reported measures of disease severity, quality of life, and emotional impact would correlate with sexual dissatisfaction among patients receiving treatment for hand/upper extremity conditions. Methods: Patients were prospectively enrolled for hand questionnaire participation. Patients with valid responses to the following questions were included: functionality, hand appearance satisfaction, symptom severity, emotional dissatisfaction, sexual dissatisfaction, and treatment satisfaction. Composite scores were created and scored. Sexual dissatisfaction composite scores were compared through Spearman correlation coefficient analysis to quality of life, emotional dissatisfaction, hand appearance, symptom severity, and hand functionality. Results: High levels of diminished quality of life correlated with sexual dissatisfaction (rs = 0.748, P < 0.001). Increased emotional dissatisfaction correlated with sexual dissatisfaction (rs = 0.827, P < 0.001). Increased satisfaction with hand appearance negatively correlated with sexual dissatisfaction (rs = -0.648, P = 0.001). Increased levels of dissatisfaction with hand functionality correlated with sexual dissatisfaction (rs = 0.526, P = 0.005). Conclusions: The correlation between sex life and quality of life may allow surgeons to improve patient satisfaction when treating hand/upper extremity issues. The relationship between sex life and emotional dissatisfaction emphasizes the impact that sexual dissatisfaction has on patients' lives. Evaluating the relationship between hand appearance and sexual dissatisfaction may indicate that patient self-perception of hand attractiveness plays a role in sex life.

14.
Hand (N Y) ; : 15589447221124233, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36205307

RESUMO

BACKGROUND: The purpose of this study was to perform a biomechanical investigation on the effect of ulnar variance (UV) on the stability of the distal radioulnar joint (DRUJ) prior to and after DRUJ sectioning. METHODS: Ten cadaveric forearm specimens were included in the study and baseline UV was assessed radiographically. Radial motion relative to the ulna was evaluated using Intel real sense cameras and a custom developed program. The forearms were dissected, and a radial osteotomy was performed. Using a custom-made plate, radial stability was assessed with an UV of + 4, 0, and -4 mm by measuring the maximum and minimum radial position relative to the ulna during a simulated Shuck test. The volar radioulnar ligaments and triangular fibrocartilage complex (TFCC) were then sectioned, and testing was repeated at each UV state. RESULTS: Sectioning significantly increased radial translation at neutral (P = .008), +4 mm UV (P = .008), and -4 mm UV (P = .018). There were no significant differences in translation between the 3 UV groups with the DRUJ intact (P = .124). The ulnar negative (-4 mm) state had significantly lower translation compared to the positive (+4 mm) (P < .001) and the neutral (0 mm) (P = .026) UV states. There were no significant differences between the positive and neutral UV groups with the DRUJ sectioned. CONCLUSIONS: Fixating the radius in -4 mm of ulnar negativity significantly decreased radial translation after sectioning the volar radioulnar ligament and TFCC. Ulnar variance had no effect on stability with an intact DRUJ. STUDY TYPE: Biomechanical Study.

15.
J Hand Microsurg ; 14(3): 245-250, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36016633

RESUMO

Introduction We evaluated the demographics, flap types, and 30-day complication, readmission, and reoperation rates for upper extremity free flap transfers within the National Surgical Quality Improvement Program (NSQIP) database. Materials and Methods Upper extremity free flap transfer patients in the NSQIP from 2008 to 2016 were identified. Complications, reoperations, and readmissions were queried. Chi-squared tests evaluated differences in sex, race, and insurance. The types of procedures performed, complication frequencies, reoperation rates, and readmission rates were analyzed. Results One-hundred-eleven patients were selected (mean: 36.8 years). Most common upper extremity free flaps were muscle/myocutaneous (45.9%) and other vascularized bone grafts with microanastomosis (27.9%). Thirty-day complications among all patients included superficial site infections (2.7%), intraoperative transfusions (7.2%), pneumonia (0.9%), and deep venous thrombosis (0.9%). Thirty-day reoperation and readmission rates were 4.5% and 3.6%, respectively. The mean time from discharge to readmission was 12.5 days. Conclusion Upper extremity free flap transfers could be performed with a low rate of 30-day complications, reoperations, and readmissions.

16.
J Wrist Surg ; 11(3): 250-256, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35845237

RESUMO

Background The scapholunate interosseous ligament (SLIL) couples the scaphoid and lunate, preventing motion and instability. Prior studies suggest that damage to the SLIL may significantly alter contact pressures of the radiocarpal joint. Questions/Purposes The purpose of this study was to investigate the contact pressure and contact area in the scaphoid and lunate fossae of the radius prior to and after sectioning the SLIL. Methods Ten cadaveric forearms were dissected distal to 1-cm proximal to the radiocarpal joint and a Tekscan sensor was placed in the radiocarpal joint. The potted specimen was mounted and an axial load of 200 N was applied over 60 seconds. Results Sectioning of the SLIL did neither significantly alter mean contact pressure at the lunate fossa ( p = 0.842) nor scaphoid fossa ( p = 0.760). Peak pressures were similar between both states at the lunate and scaphoid fossae ( p = 0.301-0.959). Contact areas were similar at the lunate fossa ( p = 0.508) but trended toward an increase in the SLIL sectioned state in the scaphoid fossa ( p = 0.055). No significant differences in the distribution of contact pressure ( p = 0.799), peak pressure ( p = 0.445), and contact area ( p = 0.203) between the scaphoid and lunate fossae after sectioning were observed. Conclusion Complete sectioning of the SLIL in isolation may not be sufficient to alter the contact pressures of the wrist. Clinical Relevance Injury to the secondary stabilizers of the SL joint, in addition to complete sectioning of the SLIL, may be needed to induce altered biomechanics and ultimately degenerative changes of the radiocarpal joint.

17.
Hand (N Y) ; : 15589447221105542, 2022 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-35815611

RESUMO

BACKGROUND: Previous studies have suggested that proximal row carpectomy (PRC) results in increased contact pressures and decreased contact areas in the radiocarpal joint. Such experiments, however, used older technologies that may be associated with considerable measurement errors. The purpose of this study was to determine whether there was a significant difference in contact pressure and contact area before and after PRC using Tekscan, a newer pressure sensing technology. METHODS: Ten nonpaired cadaveric specimens were dissected proximal to the carpal row and potted. An ultra-thin Tekscan sensor was secured in the lunate fossa of the radius. The wrists were loaded with 200 N of force for 60 seconds to simulate clenched-fist grip; contact pressure and area was assessed before and after PRC. RESULTS: Performing a PRC did not significantly increase mean contact pressure at the lunate fossa compared to the native state (mean increase of 17.4 ± 43.2 N/cm2, P = .184). Similarly, the PRC did not significantly alter peak contact pressures at the lunate fossa (intact: 617.2 ± 233.46 N/cm2, median = 637.5 N/cm2; PRC: 707.8 ± 156.6 N/cm2, median = 728.5 N/cm2; P = .169). In addition, the PRC (0.46 ± 0.15 cm2, median = 0.48 cm2) and intact states (0.49 ± 0.25 cm2, median = 0.44 cm2) demonstrated similar contact areas (P = .681). CONCLUSIONS: In contrast to prior studies that demonstrated significant increases in contact pressure and decreases in contact area after PRC, our findings propose that performing a PRC does not significantly alter the contact pressures or area of the lunate fossa of the radiocarpal joint.

18.
J Clin Med ; 11(13)2022 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-35807138

RESUMO

As surgical management of carpal tunnel release (CTR) becomes ever more common, extensive research has emerged to optimize the contextualization of this procedure. In particular, CTR under the wide-awake, local-anesthesia, no-tourniquet (WALANT) technique has emerged as a cost-effective, safe, and straightforward option for the millions who undergo this procedure worldwide. CTR under WALANT is associated with considerable cost savings and workflow efficiencies; it can be safely and effectively executed in an outpatient clinic under field sterility with less use of resources and production of waste, and it has consistently demonstrated standard or better post-operative pain control and satisfaction among patients. In this review of the literature, we describe the current findings on CTR using the WALANT technique.

19.
J Plast Reconstr Aesthet Surg ; 75(8): 2625-2636, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35644885

RESUMO

PURPOSE: Elbow flexion is one of the most important functions to restore following brachial plexus damage. The authors sought to systematically review available evidence to summarize outcomes of free gracilis and non-free muscle transfers in restoring elbow flexion. METHODS: MEDLINE, EMBASE, and Cochrane were searched to identify articles reporting on elbow flexion reanimation in terms of transfer failure rates, strengths, range of motion (ROM), and/or Disabilities of the Arm, Shoulder and Hand (DASH) scores. A systematic review was chosen to select studies and reported according to PRISMA guidelines. RESULTS: Forty-six studies met the inclusion criteria for this study. A total of 432 cases were gracilis free-flap muscle transfers (FFMT), and 982 cases were non-free muscle transfers. FFMT were shown to have higher Medical Research Council (MRC) strength scores than non-free muscle transfer groups. However, 42 studies, totaling 1,266 cases, were useful in evaluating graft failure, showing failure (MRC<3) in 77/419 (∼18.4%) of gracilis free-flap transfers and 215/847 (∼25.4%) of non-free muscle transfers. Sixteen articles, 285 cases, were useful to evaluate ROMs (total range: 0-140°), and eight articles, 215 cases, provided DASH scores (total range: 8-90.8). CONCLUSIONS: Of patients who underwent gracilis FFMT procedures, higher mean strength scores and lower failure rates were observed when compared with non-free muscle transfers. Articles reporting non-free muscle transfer procedures (pectoralis, pedicled, Steindler, vascularized ulnar nerve grafts, Oberlin, single/double nerve transfers) provided comprehensive insight into outcomes and indicated that they may result in pooerer poorer DASH scores and ROM.


Assuntos
Neuropatias do Plexo Braquial , Plexo Braquial , Articulação do Cotovelo , Músculo Grácil , Transferência de Nervo , Plexo Braquial/cirurgia , Neuropatias do Plexo Braquial/cirurgia , Cotovelo , Articulação do Cotovelo/inervação , Músculo Grácil/transplante , Humanos , Transferência de Nervo/métodos , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica , Resultado do Tratamento
20.
Plast Surg (Oakv) ; 30(2): 122-129, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35572084

RESUMO

Background: The use of minor field sterility in hand/upper extremity cases has been shown to improve workflow efficiency while maintaining patient safety. As this finding has been limited to specific procedures, we investigated the safety of performing a wide array of hand/upper extremity procedures outside the main operating room using minimal field sterility with Wide-Awake Local Anaesthesia No Tourniquet (WALANT) anaesthesia by evaluating superficial and deep infection rates across a diverse series of cases. Methods: This study was a case series conducted between October 2017 and June 2020. Of all, 217 patients underwent hand/upper extremity procedures performed in a minor procedure room via WALANT technique with field sterility. Primary outcome measures include superficial and deep surgical site infections within 14 days post-surgery. Results: Of all, 217 patients were included in this study; 265 consecutive hand/upper extremity operations were performed by a single surgeon, with notable case diversity. The majority of patients (n = 215, 99.1%) did not report or present with signs of infection before or after their operation. We report 0% 14-day and 0.37% 30-day surgical site infection rates for such hand/upper extremity procedures performed in a minor procedure room with field sterility. Conclusion: Hand/upper extremity procedures performed via WALANT technique with field sterility in a minor procedure room are associated with low surgical site infection rates. These rates are comparable to surgical site infection rates for similar surgeries performed in main operating rooms with standard sterilization procedures. Thus, the implementation of this technique may allow for improved workflow efficiency and reduced waste, all while maintaining patient safety.


Historique: Il est démontré que le recours à un champ stérile mineur dans les interventions de la main et des extrémités supérieures améliore le déroulement du travail tout en maintenant la sécurité du patient. Comme cette observation se limite à des interventions particulières, les chercheurs ont examiné la sécurité d'un large éventail d'interventions de la main et des extrémités supérieures au moyen de la technique d'anesthésie de WALANT (acronyme anglais d'anesthésie locale en plein éveil sans tourniquet) hors de la salle d'opération principale. Pour ce faire, ils ont évalué le taux d'infections superficielles et profondes dans une série de cas variés. Méthodologie: La présente série de cas a été réalisée entre octobre 2017 et juin 2020. Au total, 217 patients ont subi une intervention mineure de la main ou des extrémités supérieures exécutée dans une salle d'intervention mineure sur champ stérile au moyen de la technique d'anesthésie de WALANT. Les mesures de résultat primaire incluaient des infections superficielles et profondes au foyer chirurgical dans les 14 jours suivant l'intervention. Résultats: Au total, 217 patients ont participé à l'étude. Un seul chirurgien a effectué 265 opérations consécutives de la main ou des extrémités supérieures, d'une diversité remarquable. La majorité des patients (n = 215, 99,1 %) n'ont pas déclaré ni présenté de signes d'infection avant ou après leur opération. Les chercheurs ont déclaré un taux d'infection de 0 % au foyer chirurgical au bout de 14 jours et de 0,37 % au bout de 30 jours pour les interventions de la main et des extrémités exécutées sur champ stérile dans une salle d'intervention mineure. Conclusion: Les interventions de la main et des extrémités supérieures exécutées sur champ stérile par la technique d'anesthésie de WALANT dans une salle d'intervention mineure sont liées à un faible taux d'infection au foyer chirurgical. Ces taux sont comparables à ceux des infections au foyer chirurgical lors d'interventions semblables exécutées dans une salle d'opération principale dotée d'interventions de stérilisation standard. Ainsi, la mise en œuvre de cette technique pourrait améliorer le déroulement du travail et réduire le gaspillage, tout en maintenant la sécurité du patient.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...